Roland VG-88 Instrukcja Użytkownika Strona 3

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 20
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 2
3
MIDI Implementation
4. ADDRESS MAPPING OF PARAMETER
The address and size are displayed under 7-bit hexadecimal notation.
Address MSB LSB
Binary 0aaa aaaa 0bbb bbbb 0ccc cccc 0ddd dddd
7-bit Hexadecimal AA BB CC DD
Address MSB LSB
Binary 0sss ssss 0ttt tttt 0uuu uuuu 0vvv vvvv
7-bit Hexadecimal SS TT UU VV
Address Block Map
----------------------------------------------------------------------------------------------
Address Block Sub Block Note
00 00 00 00 +------------------------------------------+
| DISPLAY CONTRAST | *Refer to Table 'DISPLAY'
+------------------------------------------+
01 00 00 00 +------------------------------------------+
| GK FUNC | *Refer to Table 'GK FUNC'
+------------------------------------------+
02 00 00 00 +------------------------------------------+
| GLOBAL | *Refer to Table 'GLOBAL'
+------------------------------------------+
03 00 00 00 +------------------------------------------+
| TUNER | *Refer to Table 'TUNER'
+------------------------------------------+
04 00 00 00 +------------------------------------------+
| OUTPUT SELECT | *Refer to Table 'OUTPUT SELECT'
+------------------------------------------+
05 00 00 00 +-------------------+ +--------------------+
| SYSTEM | | DRIVER | *Refer to Table 'DRIVER'
| | +--------------------+
06 00 00 00 | | +--------------------+
| | | PEDAL | *Refer to Table 'PEDAL'
| | +--------------------+
07 00 00 00 | | +--------------------+
| | | DIAL | *Refer to Table 'DIAL'
| | +--------------------+
09 00 00 01 | | +--------------------+
| | | MIDI | *Refer to Table 'MIDI'
| | +--------------------+
09 00 02 00 | | +--------------------+
| | | PROGRAM MAP(BANK0) | *Refer to Table 'PROGRAM MAP(BANK0)'
| | +--------------------+
09 00 04 00 | | +--------------------+
| | | PROGRAM MAP(BANK1) | *Refer to Table 'PROGRAM MAP(BANK1)'
| | +--------------------+
09 00 06 00 | | +--------------------+
| | | PROGRAM MAP(BANK2) | *Refer to Table 'PROGRAM MAP(BANK2)'
+-------------------+ +--------------------+
0C 00 00 00 +-------------------+ +--------------------+
| USER Patch | | #1-1 | *Refer to Table 'PATCH'
| | +--------------------+
0C 01 00 00 | | +--------------------+
| | | #1-2 |
| | +--------------------+
: | | :
: | | :
0C 62 00 00 | | +--------------------+
| | | #25-3 |
| | +--------------------+
0C 63 00 00 | | +--------------------+
| | | #25-4 |
+-------------------+ +--------------------+
0E 00 00 00 +-------------------+ +--------------------+
| PRESET Patch | | #26-1 | *Refer to Table 'PATCH'
| | +--------------------+ (Read only)
0E 01 00 00 | | +--------------------+
| | | #26-2 |
| | +--------------------+
: | | :
: | | :
0E 7F 00 00 | | +--------------------+
| | | #57-4 |
| | +--------------------+
0F 00 00 00 | | +--------------------+
| | | #58-1 |
| | +--------------------+
: | | :
: | | :
0F 1E 00 00 | | +--------------------+
| | | #65-3 |
| | +--------------------+
0F 1F 00 00 | | +--------------------+
| | | #65-4 |
+-------------------+ +--------------------+
----------------------------------------------------------------------------------------------
* Bulk data can be received only in the load-ready state of the MIDI parameter screen.
* In order to receive a data request, select the load-ready state in the MIDI parameter screen.
* When a data request is received, the data is transmitted in units of blocks that include the specified address (specified by the upper two bytes of the address).
* Parameters for which Size is 2 or higher should not be separated; make sure these are sent in the same packet.
Przeglądanie stron 2
1 2 3 4 5 6 7 8 ... 19 20

Komentarze do niniejszej Instrukcji

Brak uwag