Dec.2004
SYSTEM SOFTWARE
UPDATING INSTRUCTIONS
Required items
* In order to play back the update data, you will need a means to play back SMF
data.
We recommend a computer + UM-2 + UpdSMF.exe (UpdSMFJ.exe).
In the explanation that follows, we assume that you are using a computer +
UM-2 + UpdSMF.exe (UpdSMFJ.exe).
1. SMF data for the update CD-ROM (#17041565)
_0000001.mid - _0000021.mid
2. SMF playback system
Computer with USB connector (the UM-2 driver must be installed)
UM-2
UpdSMF.exe (English version) or UpdSMFJ.exe (Japanese version)
3. Adaptor BRC series
4. MIDI cable
Update procedure
* As a precaution, please make a backup of the user data before you continue.
1. Connect the MIDI OUT 1 (or 2) of your MIDI playback system (computer
+ UM-2) to the DR-880s MIDI IN.
2. While holding down [SHIFT] + [EDIT], power-on the DR-880.
fig.system1
3. Start up UpdSMF.exe (UpdSMFJ.exe), and make the following settings.
MIDI Out Device =1: EDIROL UM-2 MIDI 1 (or 2)
SMF Path = the directory that contains the update SMF data
4. Click Scan SMF.
Verify that you see the update data (_0000001.mid - _0000021.mid).
5. Click Send.
The update will begin.
* Don’t turn off the power during the update. Doing so may destroy the user
memory.
During the update, the following screens will alternate. The FAVORITE [1]-[4]
button LEDs will blink.
fig.system2
fig.system3
6. When the update is finished, the following display will appear.
Verify the checksum (Prg1, Prg2).
fig.system4
7. Power-off the DR-880.
TEST MODE
Required items
1. Oscillator
2. Oscilloscope
3. Monitor amp
4. Noise meter
5. Ammeter
6. FS-5U
7. EV-5
8. D/A converter
9. Computer
Supported OS: Windows XP/2000/Me or later
10. MIDI cable
11. USB cable
Preparations for test mode
Oscilloscope settings
TIME/DIV: 1 [msec]
VOLT/DIV: 2 [V]
Oscillator
1. Waveform: square wavefrequency: 200 [Hz], amplitude: 100 [mVp-p]
2. Waveform: sine wavefrequency: 200 [Hz], amplitude: -10 [dBu]
Noise meter
FILTER: JIS-A
FS-5U
Set the POLARITY switch toward the jack.
EV-5
Set the MIN VR to 0
DR-880
GUITAR/BASS INPUT VR = MAX
DRUM VR = MAX
BASS VR = MAX
MASTER VR = MAX
Flash-ROM Updater
CPU
1.00 0007 2004/05/13
EXT
1.00 0103 2004/09/27
Flash-ROM Updater
adrs 0x00******
Receiving...
Flash-ROM Updater
adrs 0x00******
sum 0x****
Waiting...
Flash-ROM Updater
adrs 0x0044FFF0
sum 0x****
Completed.
sum(prg1)0x****
sum(prg2)0x****